Professional Haloo Vending Machine Manufacturer & Supplier.
What happens if the unmanned vending machine has insufficient refrigerant and overcharged? The author of the Dongguan unmanned vending machine manufacturer is here to introduce to you what happens when the unmanned vending machine has insufficient refrigerant and overfilling. 1. Failure phenomenon and reasons of insufficient refrigerant of unmanned vending machine 1. Failure phenomenon: the whole machine of unmanned vending machine has poor refrigeration effect, the air at the outlet is a bit cool, and the pressure on the high pressure side and low pressure side is found to be both Low (when the compressor speed is 2000r/min and the ambient temperature is about 35°C, the low-pressure meter index is less than 1kg/cm2, and the high-pressure meter index is less than 10kg/cm2), and the flow of bubbles can be seen in the sight glass. 2. The cause of the failure: The refrigeration system of the unmanned vending machine has refrigerant leakage points, which leads to insufficient refrigerant. 3. Treatment method: 1) Use an electronic leak detector to find out the leak point and repair or replace parts. 2) If the parts are not replaced, only a proper amount of refrigerant can be added; if the parts are replaced, a proper amount of refrigerating oil should be added as required, and the system should be evacuated to add enough refrigerant. 2. Dongguan unmanned vending machine manufacturers remind unmanned vending machines to refill excessive refrigerant failure phenomenon and treatment methods 1. Failure phenomenon: the unmanned vending machine has poor cooling effect, and the high pressure side is found when checked with a manifold pressure gauge. , The pressure on the low-pressure side is too high (when the compressor speed is about 2000r/min and the ambient temperature is 35℃, the pressure of the high-pressure gauge is about 19kg/cm2, and the pressure of the low-pressure gauge is 2.3kg/cm2, and there is no indication in the sight glass. The air bubbles flow. 2. The reason for the failure: the refrigeration system is filled with too much refrigerant, so that the refrigeration capacity cannot be fully exerted, resulting in poor refrigeration effect. 3. Treatment method: connect the manifold pressure gauge to the refrigeration system of the unmanned vending machine , Slowly loosen the manual valve on the low-pressure side of the manifold pressure gauge to allow the refrigerant to be discharged slowly (not from the high-pressure side, because the refrigerant from the high-pressure side will bring out a large amount of refrigerant oil) until the pressure on the high and low sides is normal. The refrigerant can be seen in the liquid mirror to flow clearly, and occasionally there are bubbles flowing through. The above content is organized and released for you by the author of the Dongguan unmanned vending machine manufacturer. If you need to know more about the unmanned vending machine, please click Enter an article on our company's official website: Why is it said that the social value of unmanned vending containers is greater?